roof-and-wall-bracing-system

For transfer of wind force and other acting loads form building frame to the foundation at certain interval x-bracing system is used to change the direction of forces for reducing the impact of forces. Normally 2nd and 2nd last bays are preferably designed as braced bay and in between every 4th bay shall be braced bay for economical reason. These braced bays are for roof as well as wall between two frames (bay). Some time roof bracing and wall bracing may be in adjoining bays separately. However the stability of the structure shall be checked first before doing so. Normally rod, pipes or angles are used for x-bracing purpose. Wall bracings are laid between two columns form haunch to bottom of columns

Vibgyor Steel, Al Hamra, Ras Al Khaimah, UAE, 📞 +971 7243 4599, 📞 +971 7243 4598, 📞 sales@vibgyorsteel.org,sales@vibgyorsteel.com